Sun Jun 21 21:23:46 2009 UTC ()
Add example configuration files


(agc)
diff -r0 -r1.1 src/external/bsd/iscsi/dist/src/examples/1.conf
diff -r0 -r1.1 src/external/bsd/iscsi/dist/src/examples/2.conf
diff -r0 -r1.1 src/external/bsd/iscsi/dist/src/examples/3.conf
diff -r0 -r1.1 src/external/bsd/iscsi/dist/src/examples/4.conf

File Added: src/external/bsd/iscsi/dist/src/examples/1.conf
# Simple file showing 1 extent, device and target

# extent
# name	storage			offset (in bytes) 	size
extent0	/tmp/iscsi-target0	0			100MB

# devices
# name	resilience	devices/extents
device0	RAID0		extent0

# targets
# name	device		netmask
target0	device0		10.4.0.0/16



# NB, in the above, the intermediate device definition is not necessary.
# It could have been simply:
extent1	/tmp/iscsi-target1	0			100MB
target1	extent1		10.4.0.0/16

File Added: src/external/bsd/iscsi/dist/src/examples/2.conf
# Complex file showing 3-way RAID1 (with RAID1 components),
# also using local and (NFS) remote components

# extents
extent0	/iscsi/extents/0			0	100MB
extent1	/imports/remote1/iscsi/extents/0	0	100MB
extent2	/iscsi/extents/1			0	100MB
extent3	/imports/remote1/iscsi/extents/1	0	100MB
extent4	/iscsi/extents/2			0	100MB
extent5	/imports/remote1/iscsi/extents/2	0	100MB

# devices
device0	RAID1		extent0 extent1
device1	RAID1		extent2 extent3
device2	RAID1		extent4 extent5
device3	RAID1		device0 device1 device2

# targets
target0	device3		10.4.0.0/16

File Added: src/external/bsd/iscsi/dist/src/examples/3.conf
# Complex file showing 3-way RAID1 (with RAID1 components),
# also using local and (NFS) remote components

# extents
extent0	/iscsi/extents/0			0	100MB
extent1	/imports/remote1/iscsi/extents/0	0	100MB
extent2	/iscsi/extents/1			0	100MB
extent3	/imports/remote1/iscsi/extents/1	0	100MB
extent4	/iscsi/extents/2			0	100MB
extent5	/imports/remote1/iscsi/extents/2	0	100MB
extent6	/iscsi/extents/3			0	100MB

# devices
device0	RAID1		extent0 extent1
device1	RAID1		extent2 extent3
device2	RAID1		extent4 extent5
device3	RAID1		device0 device1 device2
device4	RAID0		extent6

# targets
target0	device3		10.4.0.0/16
target1	device4		127.0.0.0/8

File Added: src/external/bsd/iscsi/dist/src/examples/4.conf
# Complex file showing 3-way RAID1 (with RAID1 components),
# also using local and (NFS) remote components

# extents
extent0	/iscsi/extents/0			0	100MB
extent1	/imports/remote1/iscsi/extents/0	0	100MB
extent2	/iscsi/extents/1			0	100MB
extent3	/imports/remote1/iscsi/extents/1	0	100MB
extent4	/iscsi/extents/2			0	100MB
extent5	/imports/remote1/iscsi/extents/2	0	100MB
extent6	/iscsi/extents/3			0	100GB

# devices
device0	RAID1		extent0 extent1
device1	RAID1		extent2 extent3
device2	RAID1		extent4 extent5
device3	RAID1		device0 device1 device2

# targets
target0	device3		10.4.0.0/16

# a target can be made from just an extent
target1	extent6		127.0.0.0/8